Microtrac Nanotrac Wave II
Microtrac Nanotrac Wave II

Accurate particle size zeta potential analyser ideal for characterising nanoparticles.

Featuring an enhancement to traditional DLS, the Nanotrac Wave II employs Reference Beating, which amplifies the signal back to the photodector, producing unparalleled accuracy for measuring particle size, zeta potential, molecular weight, and concentration of colloidal systems. The Nanotrac Wave II provides users with superior particle analysis capability by taking advantage of an enhanced optical signal, innovative probe technology, and advanced algorithms. Whether your material is in ppm concentration or near a finished product, the Wave II obtains fast, sensitive, and precise measurements of materials ranging from sub-nanometres to several micrometres. Reference Beating increases the optical signal between 100 to 1,000,000 times compared to traditional DLS. The increased optical signal enables users to accurately measure single and multi-mode distributions across the widest concentration range in the market. Dubbed appropriately, the Microtrac Way, check out this short presentation to learn more about our proprietary technology. Applications for the Nanotrac Wave II:
  • Pharmaceuticals/Biotechnology
  • Chemicals
  • Food/Beverage
  • Plastics/Polymers
  • Coatings/Coverings
  • Inks
  • Adhesives
  • Academic Research
Nanotrac Wave II instrument details:
  • Enhanced optical signal for superior accuracy compliments of Reference Beating – available only from Microtrac
  • Unique probe design, fixed optics, and 180° backscatter collection enables fast and precise measurement across the widest concentration range – from ppm to near solids (40% w/v)
  • Measures particles ranging in size from 0.8 to 6,500 nanometres
  • No “a priori” or advance knowledge of the particle size distribution is required
  • Able to measure Zeta Potential closer to iso-electric point by eliminating errors caused by electro-osmotic flow. ZP measurement ranges from -200 to +200mV
  • User selectable data presentation modes
  • ISO 22412 and CFR21 Part 11 compliant
  • Distribution – standard volume particle size distribution
  • Legacy – ensure data consistency when transitioning from “legacy” instrument
  • Mode – simultaneously measure size and concentration.
  • Removable sample cell – available in Teflon or stainless steel
  • 150 µl sample volume required – ideal for expensive materials
  • Peltier temperature control device
  • Multiple flow cell options – ability to connect a titrator.
15nm and 120nm bi-mode ? No problem for the Nanotrac Wave II.

[media-downloader media_id="4457" texts="Download the datasheet of the Nanotrac Wave II"]

[media-downloader media_id="4472" texts="Download Microtrac DLS product family brochure"]

Lire la suite
Microtrac Nanotrac Wave II Q
Microtrac Nanotrac Wave II Q
Nanoparticle size analyser accurately measures colloidal systems across wide concentration range. The Nanotrac Wave II Q combines the best of both worlds for nanoparticle size analysis; Microtrac’s proprietary probe technology, adapted for a cuvette interface, facilitating fast measurements and the ability to dispose of the sample cell after use. Using Reference Beating, an enhancement to traditional DLS, the Nanotrac Wave II Q delivers an amplified optical signal back to the photodetector, resulting in superior measurement accuracy for measuring size and molecular weight of nanoparticle suspensions. Providing unparalleled characterization results, the Nanotrac Wave II takes full advantage of the amplified optical signal, probe technology fixed at the cuvette interface, and advanced algorithms. From ppm to near finished product, the Nanotrac Wave II Q determines fast, repeatable, and sensitive measurements of particles ranging from sub-nanometer to several micrometer. Even with a cuvette, Reference Beating increases the optical signal between 100 to 1,000,000 times compared to traditional DLS. Users can accurately measure single and multi-modal distributions across a broad concentration range. Check out this short presentation that explains our proprietary technology, appropriately titled, the Microtrac Way. Applications for the Nanotrac Wave II Q:
  • Pharmaceuticals/Biotechnology
  • Chemicals
  • Food/Beverage
  • Plastics/Polymers
  • Coatings/Coverings
  • Inks
  • Adhesives
  • Academic Research
Nanotrac Wave II Q Analyser Details:
  • Measures particle size from 0.8 to 6,500 nanometres
  • No blank measurement or prior knowledge of the size distribution required – simply load cuvette and measure
  • Compatible with 4 cuvette volumes:
    • Macro volume – 1000 μl
    • Glass – 1000 μl
    • Semi-micro volume – 300 μl
    • Micro volume – 50 μl
  • Simultaneously measure size and concentration.
  • Widest concentration range on the market from ppm to 40% w/v
  • Cuvette error detection alerts
  • Peltier temperature control device
  • ISO 22412 and CFR21 Part 11 compliant